Temperature Metrology
Calibration Bath Stirred Liquid or Dry Block Extra Large Calibration Volume T-35NLL / T-300PLL
PRODUCT FEATURES
• The T-35NLL generates temperatures from -35 °C to 140 °C, and the T-300PLL from ambient temperature to 300 °C.
• Stirred Liquid or Dry Block.
• Extra large calibration volume: 59 mm diameter x 200 mm height.
• High Stability, Uniformity and Accuracy. Easily performs 1/5 and 1/10 DIN Pt-100 calibrations.
• Optional temperature measurement and control by external probe with Callendar-Van Dusen coefficients.
• Resolution of 0.01 °C.
• Stability of ± 0.02 °C for T-35NLL and ± 0.05 °C for T-300PLL.
• Have input for thermocouples, resistance thermometers and thermoswitches.
• Internal regulated 24 Vdc power supply and mA input for 2-wire transmitters.
• Completely automatic calibration with or without the use of a computer.
• Documenting capabilities: connection with computer and ISOPLAN® Calibration Software.
Calibration Climatic Chamber
PRODUCT FEATURES
Calibration climatic chamber – metrology performance:
• Perfect for calibration of air temperature and relative humidity sensors
• Superior temperature & humidity control and uniformity
• Convenient Front Access – Side Access for Cables & Probes
• Stable, silent, vibration free climatic conditions
• Data loggers and sensors calibration
• World-class metrology performance
• Mixed flow humidity control
• Cascade PID control
Climatic Chamber – Low Temperature
PRODUCT FEATURES
• Temperature and relative humidity controlled test polygon
• Material temperature & Rh resistance and product testing
• Maintaining superior temperature & Rh stability
• Sample conditioning prior to other tests
• Data loggers and sensors calibration
• World class metrology performance
• Accelerated ageing
• Stress tests
Climatic Chamber – Standard
PRODUCT FEATURES
• Temperature and relative humidity controlled test polygon
• Material temperature & Rh resistance and product testing
• Maintaining superior temperature & Rh stability
• Sample conditioning prior to other tests
• Data loggers and sensors calibration
• World class metrology performance
• Accelerated ageing
• Stress tests
Climatic Chamber – Ultra Low Temperature
PRODUCT FEATURES
• Temperature and relative humidity controlled test polygon
• Material temperature & Rh resistance and product testing
• Maintaining superior temperature & Rh stability
• Sample conditioning prior to other tests
• Data loggers and sensors calibration
• World class metrology performance
• Accelerated ageing
• Stress tests
Dry Block TA-60NL
PRODUCT FEATURES
• All Advanced Functions and Communication features of our Advanced Series.
• Process the ITS-90 and Callendar-Van Dusen coefficients.
• 35 mm diameter and 160 mm length Solid insert or Liquid Bath insert.
• Very Silent operation with regulated ventilation for use in laboratory.
Dry Blocks for Temperature Calibration – (large calibration volume) – T-25NL / T-45NL / T-660PL
PRODUCT FEATURES
• Model T-25NL and T-45NL are 3 in 1 temperature calibrator: dry block, stirred liquid bath for glass thermometers and any shape of temperature sensors and a Black Body source for infrared pyrometers. The T-660PL comes with a dry block and, optionally, a Black Body source.
• Calibration volume of 35 x 160 mm for the T-25NL and T-45NL and 36 x 155 mm for the T-660PL.
• The T-660PL generates temperatures from ambient to 650 °C. The T-25NL and T-45NL generate temperatures from –25 °C to 140 °C and –45 °C to 140 °C, respectively, in ambient temperature of 23 °C.
• Stability of ± 0.02 °C for the T-25NL and T-45NL and ± 0.05 °C for the T-660PL model.
• External reference thermometer not necessary.
• Completely automatic calibration with or without the use of a computer.
• Documenting capabilities: connection with computer and ISOPLAN-5 calibration software.
• Portable, compact, with carrying case and interchangeable inserts.
Dry Blocks for Temperature Calibration – (large calibration volume) – TA-25NL / TA-45NL
PRODUCT FEATURES
• 3 in 1 Temperature Calibrators: dry block, stirred liquid bath for glass thermometers and any shape of temperature sensors and a Black Body source for infrared pyrometers.
• Calibration volume of 35 x 160 mm.
• TA-25NL and TA-45NL generate temperatures from -25 °C to 140 °C and -45 °C to 140 °C, respectively, in an ambient temperature of 23 °C.
• Optional temperature measurement and control by external probe with Callendar-Van Dusen coefficients.
• Accuracy of up to ±0.1 °C with the internal reference, ±0.07 °C with the external probe or ±0.05 °C using an external thermometer such as Presys Super Thermometer ST-501.
• Stability of ±0.02 °C.
• Uniformity of ±0.05 °C.
• Input for RTD, thermocouples and thermoswitches.
• Internal regulated 24 Vdc power supply and mA input for 2-wire transmitters.
• External reference thermometer not necessary.
• Completely automatic calibration with or without the use of a computer.
• Documenting capabilities: connection with computer and ISOPLAN-5 calibration software.
• Portable, compact, with carrying case and interchangeable inserts.
Dry Blocks for Temperature Calibration – (large calibration volume) – TA-350PL / TA-660PL
PRODUCT FEATURES
• The calibration of your sensors has never been so easy with the TA user-friendly interface on its large touch screen. You can get now a calibration test report at your finger tip without installing any specific software.
• The TA makes it all! It has an internal temperature standard, a calibrator for your DUT (Device Under test) measurements and an internal powerful processor to control the automatic cycling and generates the calibration reports.
• The TA dry block will also connect easily to your metrology or CMMS (Computerized Maintenance Management System) applications as it has an open and documented protocol as well as different modern way to communicate through an Ethernet, Wi-Fi or USB interface.
• TA series are available for a wide temperature range from -60 °C to 1200 °C covering most of your industrial temperature calibration needs and they are conform to EURAMET/cg-13/V03, EA Guidelines
Dry Blocks for Temperature Calibration – T-1200P
PRODUCT FEATURES
• Generates temperatures from 50 °C up to 1200 °C with a resolution of 0.1 °C.
• Allows the use of a black body insert for the calibration of infrared pyrometers.
• Using an external thermometer such as the Presys Super Thermometer PT-511, accuracy up to ±0.3 °C.
• Stability of ±0.2 °C.
• Input for RTD, thermocouples and thermoswitches.
• Internal regulated 24 Vdc power supply and mA input for 2-wire transmitters.
• External reference thermometer not necessary.
• Completely automatic calibration with or without the use of a computer.
• Documenting capabilities: connection with computer and ISOPLAN calibration software.
• Portable, compact, with carrying case and interchangeable inserts.
Dry Blocks for Temperature Calibration – T-25N / T-35N / T-50N
PRODUCT FEATURES
• Model T-50N generates the coolest temperature available for a dry block. It reaches –50 °C with in ambient temperature of 23 °C, with no need of well insulator and no need to place it under low temperature room.
• Accuracy of up to ± 0.1 °C with the internal reference or 0.05 °C using an external thermometer such as Presys Super thermometer ST-501.
• Resolution of 0.01 °C.
• Stability of ± 0.02 °C for all range of temperature.
• Input for RTD, thermocouples and thermoswitches.
• Internal regulated 24 Vdc power supply and mA input for 2-wire transmitters.
• External reference thermometer not necessary.
• Completely automatic calibration with or without the use of a computer.
• Documenting capabilities: connection with computer and ISOPLAN-5 calibration software.
• Portable, compact, with carrying case and interchangeable inserts.
Dry Blocks for Temperature Calibration – T-350P T-650P
PRODUCT FEATURES
• The T-350P and T-650P model generate from ambient temperature to 350 °C and 650 °C respectively with a resolution of 0.01 °C.
• Using a external thermometer such as Presys Super thermometer PT-511, the accuracy up to ± 0.05 °C.
• Stability of ± 0.05 °C.
• Input for RTD, thermocouples and thermoswitches.
• Internal regulated 24 Vdc power supply and mA input for 2-wire transmitters.
• External reference thermometer not necessary.
• Completely automatic calibration with or without the use of a computer.
• Documenting capabilities: connection with computer and ISOPLAN calibration software.
• Portable, compact, with carrying case and interchangeable inserts.