PRODUCTS
Calibration Bath – Ultra Low Temperature
PRODUCT FEATURES
Ultra Low temperature calibration baths: (- 90 °C to + 130 °C)
• Temperature stability (°C): ± 0.003 @ – 90 °C
• Temperature uniformity (°C): ± 0.007 @ – 90 °C
• Calibrate sensors of any dimension
• Fluid ensures perfect heat transfer
• Unique vertical flow design
• 500 mm immersion depth
• State of the art solution
• Two bath sizes
Calibration Bath Stirred Liquid or Dry Block – Extra Large Calibration Volume TA-35NLL
PRODUCT FEATURES
• 2 in 1: Stirred liquid and dry block.
• Temperature range: from -35 °C to 140 °C (TA-35NLL).
• Extra large calibration volume de 59 x 200 mm.
• Temperature measurement and control by external probe.
• External reference thermometer input with CVD or ITS-90 parameters.
• Input for RTD, thermocouples, thermoswitches or transmitters.
• Automatic calibrations and full documenting capabilities.
• Support of various data formats such as PDF, CSV, XML.
• Autocalibration of internal temperature reference with external reference.
Calibration Bath Stirred Liquid or Dry Block Extra Large Calibration Volume T-35NLL / T-300PLL
PRODUCT FEATURES
• The T-35NLL generates temperatures from -35 °C to 140 °C, and the T-300PLL from ambient temperature to 300 °C.
• Stirred Liquid or Dry Block.
• Extra large calibration volume: 59 mm diameter x 200 mm height.
• High Stability, Uniformity and Accuracy. Easily performs 1/5 and 1/10 DIN Pt-100 calibrations.
• Optional temperature measurement and control by external probe with Callendar-Van Dusen coefficients.
• Resolution of 0.01 °C.
• Stability of ± 0.02 °C for T-35NLL and ± 0.05 °C for T-300PLL.
• Have input for thermocouples, resistance thermometers and thermoswitches.
• Internal regulated 24 Vdc power supply and mA input for 2-wire transmitters.
• Completely automatic calibration with or without the use of a computer.
• Documenting capabilities: connection with computer and ISOPLAN® Calibration Software.
Calibration Climatic Chamber
PRODUCT FEATURES
Calibration climatic chamber – metrology performance:
• Perfect for calibration of air temperature and relative humidity sensors
• Superior temperature & humidity control and uniformity
• Convenient Front Access – Side Access for Cables & Probes
• Stable, silent, vibration free climatic conditions
• Data loggers and sensors calibration
• World-class metrology performance
• Mixed flow humidity control
• Cascade PID control
Climatic Chamber – Low Temperature
PRODUCT FEATURES
• Temperature and relative humidity controlled test polygon
• Material temperature & Rh resistance and product testing
• Maintaining superior temperature & Rh stability
• Sample conditioning prior to other tests
• Data loggers and sensors calibration
• World class metrology performance
• Accelerated ageing
• Stress tests
Climatic Chamber – Standard
PRODUCT FEATURES
• Temperature and relative humidity controlled test polygon
• Material temperature & Rh resistance and product testing
• Maintaining superior temperature & Rh stability
• Sample conditioning prior to other tests
• Data loggers and sensors calibration
• World class metrology performance
• Accelerated ageing
• Stress tests
Climatic Chamber – Ultra Low Temperature
PRODUCT FEATURES
• Temperature and relative humidity controlled test polygon
• Material temperature & Rh resistance and product testing
• Maintaining superior temperature & Rh stability
• Sample conditioning prior to other tests
• Data loggers and sensors calibration
• World class metrology performance
• Accelerated ageing
• Stress tests
CP11B – Power calibrator and protection relay test set
PRODUCT FEATURES
• Voltage source up to 560V
• Current source up to 120A with a single pair of current sockets
• Accuracy class 0.02% or 0.05% to calibrate digital instruments
• Single product in a single case without auxiliary amplifiers
• High burden of outputs to drive older analogue instruments
• Large color Touchscreen and Calpro 300 PCsoft
• Manual mode and automatic test procedures
Dry Block TA-60NL
PRODUCT FEATURES
• All Advanced Functions and Communication features of our Advanced Series.
• Process the ITS-90 and Callendar-Van Dusen coefficients.
• 35 mm diameter and 160 mm length Solid insert or Liquid Bath insert.
• Very Silent operation with regulated ventilation for use in laboratory.
Dry Blocks for Temperature Calibration – (large calibration volume) – T-25NL / T-45NL / T-660PL
PRODUCT FEATURES
• Model T-25NL and T-45NL are 3 in 1 temperature calibrator: dry block, stirred liquid bath for glass thermometers and any shape of temperature sensors and a Black Body source for infrared pyrometers. The T-660PL comes with a dry block and, optionally, a Black Body source.
• Calibration volume of 35 x 160 mm for the T-25NL and T-45NL and 36 x 155 mm for the T-660PL.
• The T-660PL generates temperatures from ambient to 650 °C. The T-25NL and T-45NL generate temperatures from –25 °C to 140 °C and –45 °C to 140 °C, respectively, in ambient temperature of 23 °C.
• Stability of ± 0.02 °C for the T-25NL and T-45NL and ± 0.05 °C for the T-660PL model.
• External reference thermometer not necessary.
• Completely automatic calibration with or without the use of a computer.
• Documenting capabilities: connection with computer and ISOPLAN-5 calibration software.
• Portable, compact, with carrying case and interchangeable inserts.
Dry Blocks for Temperature Calibration – (large calibration volume) – TA-25NL / TA-45NL
PRODUCT FEATURES
• 3 in 1 Temperature Calibrators: dry block, stirred liquid bath for glass thermometers and any shape of temperature sensors and a Black Body source for infrared pyrometers.
• Calibration volume of 35 x 160 mm.
• TA-25NL and TA-45NL generate temperatures from -25 °C to 140 °C and -45 °C to 140 °C, respectively, in an ambient temperature of 23 °C.
• Optional temperature measurement and control by external probe with Callendar-Van Dusen coefficients.
• Accuracy of up to ±0.1 °C with the internal reference, ±0.07 °C with the external probe or ±0.05 °C using an external thermometer such as Presys Super Thermometer ST-501.
• Stability of ±0.02 °C.
• Uniformity of ±0.05 °C.
• Input for RTD, thermocouples and thermoswitches.
• Internal regulated 24 Vdc power supply and mA input for 2-wire transmitters.
• External reference thermometer not necessary.
• Completely automatic calibration with or without the use of a computer.
• Documenting capabilities: connection with computer and ISOPLAN-5 calibration software.
• Portable, compact, with carrying case and interchangeable inserts.